Changes

Jump to: navigation, search

Wind Energy

5,024 bytes added, 11:26, 1 March 2011
/* Market Research */
*Flash Player is essential to view the Dashboard
 
=Products=
{| style="border-spacing:0;"
| style="background-color:#9999cc;"| <center>'''S No'''</center>
| style="background-color:#9999cc;"| <center>'''Company'''</center>
| style="background-color:#9999cc;"| <center>'''Product'''</center>
| style="background-color:#9999cc;"| <center>'''Specifications'''</center>
 
|-
| style="background-color:#9999cc;"| <center>'''1'''</center>
| <center>Vestas</center>
| <center>V80</center>
| Rated power 2.0 MW; Operating temperature -30°C to 40°; Frequency: 50 Hz/60 Hz;Number of poles 4-pole
 
|-
| <center>V90</center>
| Rated power 1.8/2.0 MW; Operating temperature -30°C to 40°; Frequency: 50 Hz/60 Hz;Number of poles 4-pole (50 Hz)/6-pole (60 Hz)
 
|-
| <center>V90 Offshore</center>
| Rated power 3.0 MW; Operating temperature -30°C to 40°; Frequency: 50 Hz/60 Hz;Number of poles 4-pole
 
|-
| style="background-color:#9999cc;"| <center>'''2'''</center>
| <center>North Heavy Company</center>
| <center>2 MW DFIG</center>
| <nowiki>Rated voltage 690V; rated current 1670A; frequency 50Hz; rotor rated voltage 1840V; rotor rated current 670A;, Poles 4 Pole; rated speed 1660rpm; power speed range of 520-1950rmp; Insulation Class H; protection class IP54; center height H = 500mm; motor temperature rise =<95K</nowiki>
 
|-
| style="background-color:#9999cc;"| <center>'''3'''</center>
| <center>Gamesa</center>
| <center>G90</center>
| Rated Voltage 690 V ac; Frequency 50 Hz; Protection class IP 54; Number of poles 4; Rotational speed 900:1,900 rpm (rated 1,680 rpm) (50Hz); Rated Stator Current 1,500 A @ 690 V; Power factor (standard) 0.98 CAP - 0.96 IND at partial loads and 1 at nominal power. *; Power factor (optional) 0.95 CAP - 0.95 IND throughout the power range.
 
|-
| style="background-color:#9999cc;"| <center>'''4'''</center>
| <center>Nordex</center>
| <center>N80</center>
| Rated power 2.5 MW; Rated volatge 690V; frequency 50/60Hz; Cooling systems: liquid/air.
 
|-
| <center>N90</center>
| Rated power 2.5 MW; Rated volatge 690V; frequency 50/60Hz; Cooling systems: liquid/air.
 
|-
| <center>N100</center>
| Rated power 2.4 MW; Rated volatge 690V; frequency 50/60Hz; Cooling systems: liquid/air.
 
|-
| <center>N117 </center>
| Rated power 2.5 MW; Rated volatge 690V; frequency 50/60Hz; Cooling systems: liquid/air.
 
|-
| style="background-color:#9999cc;"| <center>'''5'''</center>
| <center>Converteam</center>
| <center>DFIG</center>
| <center>NA</center>
 
|-
| style="background-color:#9999cc;"| <center>'''6'''</center>
| <center>Xian Geoho Energy Technology</center>
| <center>1.5MW DFIG</center>
| Rated power1550KW; Rated speed1755 r/min; Speed range975~1970 r/min;Stator rated voltage690V±10%; Stator rated current1115A; Rotor rated voltage320V; Rotor rated current430A;Winding connectionY / Y; Power factor0.95 (Lead) ~ 0.95Lag; Protection classIP54; Insulation classH; Work modeS1; Installation modeIM B3; Cooling modeAir cooling; Center high500mm; Pole number4; Weight6950kg
 
|-
| style="background-color:#9999cc;"| <center>'''7'''</center>
| <center>Tecowestinghouse</center>
| <center>TW450XX (0.5-1 KW)</center>
| Rated Power 0.5 -1 KW; Rated voltage : 460/ 575/ 690 V; frequency 50/ 60 Hz; No. Of Poles 4/6; Ambient Temp.(°C) -40 to 50; Speed Range (% of Synch. Speed) 68% to 134%; Power Factor (Leading) -0.90 to +0.90 ; Insulation Class H/F; Efficiency >= 96%
 
|-
| <center>TW500XX (1-2 KW)</center>
| Rated Power 1-2 kW; Rated voltage : 460/ 575/ 690 V; frequency 50/ 60 Hz; No. Of Poles 4/6; Ambient Temp.(°C) -40 to 50; Speed Range (% of Synch. Speed) 68% to 134%; Power Factor (Leading) -0.90 to +0.90 ; Insulation Class H/F; Efficiency >= 96%
 
|-
| <center>TW560XX (2-3 KW)</center>
| Rated Power 2-3kW; Rated voltage : 460/ 575/ 690 V; frequency 50/ 60 Hz; No. Of Poles 4/6; Ambient Temp.(°C) -40 to 50; Speed Range (% of Synch. Speed) 68% to 134%; Power Factor (Leading) -0.90 to +0.90 ; Insulation Class H/F; Efficiency >= 96%
 
|-
| style="background-color:#9999cc;"| <center>'''8'''</center>
| <center>Acciona </center>
| <center>AW1500</center>
| Rated Power 1500MW; Voltage 690 V ac; Frequency 50 Hz; Protection class IP 54; Number of poles 4; Rotational speed 900:1,900 rpm (rated 1,680 rpm) (50Hz); Rated Stator Current 1,500 A @ 690 V; Power factor (standard) 0.98 CAP - 0.96 IND at partial loads and 1 at nominal power. *; Power factor (optional) 0.95 CAP - 0.95 IND throughout the power range.
 
|-
| <center>AW3000</center>
| Rated Power 3000MW; Voltage 690 V ac; Frequency 50 Hz; Protection class IP 54; Number of poles 4; Rotational speed 900:1,900 rpm (rated 1,680 rpm) (50Hz); Rated Stator Current 1,500 A @ 690 V; Power factor (standard) 0.98 CAP - 0.96 IND at partial loads and 1 at nominal power. *; Power factor (optional) 0.95 CAP - 0.95 IND throughout the power range.
 
|-
| style="background-color:#9999cc;"| <center>'''9'''</center>
| <center>General electric</center>
| <center>GE 1.5/2.5MW</center>
| Rated power 1.5/2.5 MW; Frequency (Hz) 50/60;
 
|}
 
 
 
=Market Research=
<br>
Source:[http://www.gwec.net/index.php?id=167 GWEC's Global Wind Report 2009]
 
=<span style="color:#C41E3A">Like this report?</span>=
<p align="center"> '''This is only a sample report with brief analysis''' <br>
326
edits